RANGE OF PERFORMANCE |
Flow rate up to 317 gpm
Head up to 52 ft |
LIMITS OF USE |
Depth up to 30 ft
Liquid temperature up to 104°f
Passage of solid bodies max up to 3”
For continuous duty: minimum immersion 16” from pump base |
INSTALLATION AND USE |
VXC SERIES PUMPS ARE MADE OF EXCEPTIONALLY ROBUST HEAVY-GAUGE CAST IRON, RESISTANT TO ABRASION AND LONG-LASTING, AND HAVE A VORTEX TYPE IMPELLER. THEY ARE SUITABLE FOR SEWAGE, WASTE WATER AND SLUDGE, INCLUDING WATER CONTAINING SOLIDS OR MUD. THEY ARE IDEAL FOR SEWAGE INSTALLATION, TUNNELS AND OTHER
EXCAVATIONS, UNDERGROUND CAR PARKS AND SIMILAR APPLICATIONS. |
|
|
CONSTRUCTION CHARACTERISTICS |
• PUMP BODY, MOTOR CASING: cast iron.
• IMPELLER: cast iron.
• BASE: stainless steel AISI 304.
• MOTOR SHAFT: stainless steel EN 10088-3 - 1.4057.
• DOUBLE SEAL: mechanical seal silicon carbide - widia -NBR, with oil barrier chamber and inner lip seal to protect the seal in the event of dry running.
• MOTOR: submersible asynchronous, 2 pole, for continuous duty.
VXC-L: single-phase 230V - 60 Hz
Models up to 1.5 Hp have built in thermal protection
2 Hp single-phase versions have a thermal protector
provided in the winding for connection to the control box.
VXC-L: three-phase 230V - 60 Hz.
-Thermal protectors are provided in the winding for connection
to the external control panel
• INSULATION: class F.
• PROTECTION: IP 68.
• STANDARD FEATURES:
VXC-L (single-phase) Float switch.
30 ft “H07 RN-F” submersible power cable
1 Hp to 1.5 Hp models are supplied with control box with capacitor
and manual reset motor protector.
2 Hp models are supplied with control box type
QES 300 MONO.
VXC-L (three-phase) 30 ft “H07 RN-F” neoprene power cable |
OPTIONS ON REQUEST |
• control box for three-phase pumps
• dual voltage: 230/400 V - 60 Hz
• single-phase versions without float switch
• other voltages or frequency 50 Hz |
|