RANGE OF PERFORMANCE |
Flow rate up to 118 gpm
Head up to 47ft |
LIMITS OF USE |
Depth up to 10 m
Liquid temperature up to 122°f
Liquid temperature up to 104°f for intermittent duty.
Liquid temperature up to 194°f for intermittent duty maximum 3 minutes.
Passage of solid bodies:
up to 3/4” for 0.33 hp - up to 1.5” from 0.5 Hp to 1.0 Hp
Drainage level from the bottom:
1” for 0.33 Hp - 1.5” from 0.5 Hp to 1.0 Hp |
INSTALLATION AND USE |
| RX--VORTEX PUMPS ARE SUITABLE FOR DRAINING DIRTY WATER. THE CONSTRUCTION GUARANTEES SIMPLE AND SAFE OPERATION, DUE TO THE COMPLETE COOLING OF THE MOTOR BY THE PUMPED WATER. THEY ARE RECOMMENDED FOR DOMESTIC USE, FOR DRAINING DIRTY WATER CONTAINING SUSPENDED SOLIDS. |
|
|
CONSTRUCTION CHARACTERISTICS |
• DELIVERY BODY: stainless steel AISI 304, with threaded port
• SUCTION GRID: stainless steel AISI 304.
• IMPELLER: stainless steel AISI 304.
• MOTOR SUPPORT: stainless steel AISI 304.
• MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.
• DOUBLE SEAL: mechanical seal silicon carbide - NBR, with oil barrier chamber and inner lip seal to protect the seal in the event of dry running.
• MOTOR: submersible asynchronous single-phase for continuous duty.
RXm: single-phase 115V or 230 V - 60 Hz with capacitor and thermal overload protector.
RX: three-phase 230V - 60 Hz.
• INSULATION: class F.
• PROTECTION: IP 68.
• REGISTERED MODEL
• STANDARD FEATURES:
RXm (single-phase) float switch.
Neoprene power cable “H05 RN-F”
length 15 feet
RX (three-phase) Neoprene power cable “H05 RN-F”
length 15 feet. |
OPTIONS ON REQUEST |
• special mechanical seal
• 30 feet power cable.
N.B. required for outdoor use to comply with standard EN 60335-2-41
• control box for three-phase pumps 1Hp
• single-phase versions without float switch
• other voltages or frequency 50 Hz |
|